Input Voltage | Three-phase 220V/380V/480V/660 AC | ||
Frequency | 50/60Hz | ||
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
Starting Times | It is recommended not to exceed 20 times per hour. | ||
Control Mode | (1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. | (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation. | |
Start Mode | (1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. | (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start. | |
Stop Mode | (1) Soft stop. | (2) Free stop. | |
Protective Function | (1)Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14)Incorrect wiring protection of external control stop terminals. | ||
Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. | ||
Temperature | -30 +55 oC | ||
Humidity | 90%RH without dew condensation. | ||
Vibration | <0.5G | ||
Structure | Protection Class | IP20 | |
Cooling Pattern | Natural wind cooling. |
Model | Current (A) | Standard (kW) | Heavy load (kW) | Model | Current (A) | Standard (kW) | Heavy load (kW) |
ST-GS2-5d5 | 22 | 5.5 | 4 | ST-GS2-075 | 320 | 75 | 55 |
ST-GS2-7d5 | 30 | 7.5 | 5.5 | ST-GS2-090 | 370 | 90 | 75 |
ST-GS2-011 | 45 | 11 | 7.5 | ST-GS2-115 | 400 | 115 | 90 |
ST-GS2-015 | 60 | 15 | 11 | ST-GS2-132 | 500 | 132 | 115 |
ST-GS2-018 | 75 | 18.5 | 15 | ST-GS2-160 | 560 | 160 | 132 |
ST-GS2-022 | 90 | 22 | 18.5 | ST-GS2-185 | 630 | 185 | 160 |
ST-GS2-030 | 110 | 30 | 22 | ST-GS2-200 | 800 | 200 | 185 |
ST-GS2-037 | 150 | 37 | 30 | ST-GS2-220 | 900 | 220 | 200 |
ST-GS2-045 | 180 | 45 | 37 | ST-GS2-250 | 1000 | 250 | 220 |
ST-GS2-055 | 230 | 55 | 45 | ST-GS2-280 | 1200 | 280 | 250 |
Model | Current (A) | Standard (kW) | Heavy load (kW) | Model | Current (A) | Standard (kW) | Heavy load (kW) |
ST-GS3-5d5 | 11 | 5.5 | 4 | ST-GS3-132 | 260 | 132 | 115 |
ST-GS3-7d5 | 15 | 7.5 | 5.5 | ST-GS3-160 | 320 | 160 | 132 |
ST-GS3-011 | 23 | 11 | 7.5 | ST-GS3-185 | 370 | 185 | 160 |
ST-GS3-015 | 30 | 15 | 11 | ST-GS3-200 | 400 | 200 | 185 |
ST-GS3-018 | 37 | 18.5 | 15 | ||||
ST-GS3-022 | 45 | 22 | 18.5 | ST-GS3-250 | 500 | 250 | 220 |
ST-GS3-030 | 60 | 30 | 22 | ST-GS3-280 | 560 | 280 | 250 |
ST-GS3-037 | 75 | 37 | 30 | ST-GS3-320 | 630 | 320 | 280 |
ST-GS3-045 | 90 | 45 | 37 | ST-GS3-355 | 710 | 355 | 320 |
ST-GS3-055 | 110 | 55 | 45 | ST-GS3-400 | 800 | 400 | 355 |
ST-GS3-075 | 150 | 75 | 55 | ST-GS3-450 | 900 | 450 | 400 |
ST-GS3-090 | 180 | 90 | 75 | ST-GS3-500 | 1000 | 500 | 450 |
ST-GS3-115 | 230 | 115 | 90 | ST-GS3-600 | 1200 | 600 | 500 |
Model | Current (A) | Matching motor power | Model | Current (A) | Matching motor power | ||
Standard (kW) | Heaavy load (kW) | Standard (kW) | Heaavy load (kW) | ||||
ST-GS4-5d5 | 11 | 5.5 | 4 | ST-GS4-132 | 260 | 132 | 115 |
ST-GS4-7d5 | 15 | 7.5 | 5.5 | ST-GS4-160 | 320 | 160 | 132 |
ST-GS4-011 | 23 | 11 | 7.5 | ST-GS4-185 | 370 | 185 | 160 |
ST-GS4-015 | 30 | 15 | 11 | ST-GS4-200 | 400 | 200 | 185 |
ST-GS4-018 | 37 | 18.5 | 15 | ST-GS4-250 | 500 | 250 | 200 |
ST-GS4-022 | 45 | 22 | 18.5 | ST-GS4-280 | 560 | 280 | 250 |
ST-GS4-030 | 60 | 30 | 22 | ST-GS4-320 | 630 | 320 | 280 |
ST-GS4-037 | 75 | 37 | 30 | ST-GS4-355 | 710 | 355 | 320 |
ST-GS4-045 | 90 | 45 | 37 | ST-GS4-400 | 800 | 400 | 355 |
ST-GS4-055 | 110 | 55 | 45 | ST-GS4-450 | 900 | 450 | 400 |
ST-GS4-075 | 150 | 75 | 55 | ST-GS4-500 | 1000 | 500 | 450 |
ST-GS4-090 | 180 | 90 | 75 | ST-GS4-600 | 1200 | 600 | 500 |
ST-GS4-115 | 230 | 115 | 90 |
Model | Rated power (KW) | Rated current (A) | Breaker (A) | By-pass contactor(A) | Cable size (mm2) |
XX-XX3-5d5 | 5.5 | 11 | 16 | 16 | 4 mm2 |
XX-XX3-7d5 | 7.5 | 15 | 20 | 16 | 4 mm2 |
XX-XX3-011 | 11 | 23 | 32 | 25 | 6 mm2 |
XX-XX3-015 | 15 | 30 | 40 | 40 | 10 mm2 |
XX-XX3-018 | 18 | 37 | 50 | 40 | 10 mm2 |
XX-XX3-022 | 22 | 43 | 63 | 63 | 16 mm2 |
XX-XX3-030 | 30 | 60 | 80 | 63 | 25 mm2 |
XX-XX3-037 | 37 | 75 | 100 | 100 | 35 mm2 |
XX-XX3-045 | 45 | 90 | 125 | 100 | 35 mm2 |
XX-XX3-055 | 55 | 110 | 160 | 160 | 35 mm2 |
XX-XX3-075 | 75 | 150 | 180 | 160 | 30×3 mm2 |
XX-XX3-090 | 90 | 180 | 225 | 250 | 30×3 mm2 |
XX-XX3-115 | 115 | 230 | 315 | 250 | 30×3 mm2 |
XX-XX3-132 | 132 | 264 | 315 | 400 | 30×4 mm2 |
XX-XX3-160 | 160 | 320 | 350 | 400 | 30×4 mm2 |
XX-XX3-185 | 185 | 370 | 400 | 400 | 30×4 mm2 |
XX-XX3-200 | 200 | 400 | 400 | 400 | 50×5 mm2 |
XX-XX3-250 | 250 | 500 | 630 | 630 | 50×5 mm2 |
XX-XX3-280 | 280 | 560 | 630 | 630 | 50×5 mm2 |
XX-XX3-320 | 320 | 640 | 630 | 630 | 50×5 mm2 |
XX-XX3-355 | 355 | 710 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-400 | 400 | 800 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-450 | 450 | 900 | 1000 | 1000 | 60×6 mm2 |
XX-XX3-500 | 500 | 1000 | 1250 | 1000 | 80×6 mm2 |
XX-XX3-600 | 600 | 1200 | 1600 | 1600 | 80×6 mm2 |
Author:
Mr. yin chang
E-mail:
Why you could choose our brake disc manufacture?First one and foremost, your would get brake discs which made of high quality materialSecond, you would gain brake discs competitive and reasonable...
The role of three-terminal regulator It is generally used in the protection circuit of DC circuit to reduce the voltage and stabilize the voltage. +The commonly used 78 series and 79 series, 78XX are...
Alternators Introduction Features: Ensures cranking and starting performance under all temperature extremes 100% full-load tested - meets or exceeds OE manufacturers' torque, amperage draw and RPM...
Model NO.: 185086610 HS Code: 8511409900 Model NO.: 185086610 HS Code: 8511409900 Bosch Starter motor 185086610Voltage:12VKW:1.2KWTeeth: 9T We supply any type of starter, they can replace BOSCH,...
Email to this supplier
Author:
Mr. yin chang
E-mail:
Copyright © 2025 YIWU JINGHONG AUTO PARTS CO.,LTD All rights reserved. Privacy Policy
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.